Introduction Beijing Huakeyi is a leading domestic manufacturer of analytical instruments and supplier of complete sets of products. We adhere to independent research and development and have launched over 70 products, including chemical water analysis instruments, combustible gas detectors/toxic gas alarms, oil analysis instruments, environmental monitoring equipment, water treatment devices, data acquisition and monitoring systems. We can provide complete industry solutions to fields such as electricity, metallurgy, new energy, environmental protection, and scientific research.

Products

Ammonia nitrogen online monitoring instrument
Ammonia nitrogen refers to the nitrogen present in water in the form of free ammonia (NH3) and ammonium ions (NH ₄+). Ammonia nitrogen is the most harmful form of nitrogen among all types, and it is a sign of water pollution. Its harm to the aquatic ecological environment is manifested in multiple aspects.
The instrument adopts automatic control for water sample collection, reaction measurement, data processing and transmission, and quickly and continuously completes the entire process of ammonia nitrogen analysis in wastewater.
According to the Nessler reagent spectrophotometry, the instrument reacts with ammonia nitrogen in the form of free ammonia or ammonia ions to form a yellow brown complex. The chromaticity of the complex is directly proportional to the content of ammonia nitrogen.
Total phosphorus online monitoring instrument
Total phosphorus refers to the total amount of orthophosphate, pyrophosphate, metaphosphate, polyphosphate, and organic phosphate in water. After high-temperature digestion, various forms of phosphorus are transformed into orthophosphate and determined.
The instrument adopts automatic control for water sample collection, high-temperature digestion, reaction measurement, data processing, and data transmission to quickly and continuously complete the entire process of total phosphorus analysis in wastewater.
The instrument follows the ammonium molybdate spectrophotometric method. In an acidic solution, potassium persulfate is used as a decomposing agent to convert polyphosphate and organic phosphorus into orthophosphate. orthophosphate reacts with ammonium molybdate to form a yellow phosphorus molybdenum antimony complex, which is then reduced to phosphorus molybdenum blue with ascorbic acid. The phosphate content is then measured using a total phosphorus analyzer.
Total nitrogen online monitoring instrument
Total nitrogen (TN) refers to the total amount of dissolved nitrogen and suspended nitrogen in water, including nitrite nitrogen, nitrate nitrogen, inorganic ammonium salts, dissolved ammonia, and nitrogen in most organic nitrogen-containing compounds. The instrument adopts automatic control for water sample collection, high-temperature digestion, reaction measurement, data processing, and data transmission to quickly and continuously complete the entire process of total nitrogen analysis in water.
The instrument follows the alkaline potassium persulfate ultraviolet spectrophotometry method, and uses alkaline potassium persulfate solution as an oxidant to convert the nitrogen of nitrogen-containing compounds in the sample into nitrate under conditions of 120 ℃~124 ℃. It reacts with the colorimetric reagent to generate light yellow nitro compounds, and colorimetric determination is carried out using ultraviolet spectrophotometry.
Fluorescence dissolved oxygen online monitoring instrument
The HK-8060 Fluorescence Dissolved Oxygen Online Monitor is a high-performance online measurement instrument composed of a host and sensors. The monitor is based on the principle of fluorescence quenching to measure the oxygen content in water. Applicable to the measurement and control of oxygen in aeration tanks during sewage treatment, water environment monitoring (rivers, lakes, seawater, etc.), measurement and control of oxygen content in public water sources, measurement and control of oxygen content in fish ponds, measurement and control of oxygen content in drinking water, power, food, chemical and other industries.
Online monitoring instrument for suspended solids (sludge) concentration
The HK-8110 suspended solids (sludge) concentration online monitoring instrument adopts the scattered light method. The light emitted by the detector light source (measurement light) will reflect when it encounters the surface of suspended solids suspended in the measurement water. An optical detector set at a 130 degree angle with the light source can detect the reflected light (scattered light). Measure turbidity based on the intensity of detected scattered light and the concentration of suspended solids in water.
Sewage pH analyzer
The HK-328W sewage pH analyzer adopts a sturdy cast aluminum metal shell, which is lightweight and anti-static. It has strong anti-interference ability, pollution and corrosion resistance, long service life, and convenient installation and operation. It is mainly used for continuous monitoring of the pH value of sewage in the production process and can be widely used in fields such as power, petrochemical, and sewage treatment.
Nitrate nitrogen online monitoring instrument
The HK-8210 nitrate online monitoring instrument is a high-performance online measurement instrument composed of a host and sensors. The monitoring instrument is based on the principle of ion selective electrodes to measure the nitrate content in water; Adopting digital industrial online electrodes, corrosion-resistant, suitable for various harsh environments; Flexible online calibration can be performed to further improve measurement accuracy.
Laboratory COD analyzer
The HK-8510 COD analyzer is used to determine the chemical oxygen demand (COD) of water according to the method of rapid digestion spectrophotometry (HJ/T 399-2007). A known amount of potassium dichromate solution is added to the sample, and silver sulfate is used as a catalyst in strong sulfuric acid medium. After high-temperature digestion, the COD is determined by colorimetric method. It can be widely used for detecting surface water, groundwater, domestic sewage, industrial wastewater, and other water bodies.
Hexavalent chromium analyzer
The HK-8530 hexavalent chromium analyzer was used to determine hexavalent chromium in water according to the method of "Determination of hexavalent chromium in water - Diphenylcarbazide spectrophotometric method" (GB 7467-87). Under the reaction conditions of acidic solution, hexavalent chromium in the sample reacts with Diphenylcarbazide to form a purple red compound. The absorbance of this compound is directly proportional to the hexavalent chromium content, and colorimetric measurement is carried out using the spectrophotometric method. It can be widely used for detecting water bodies such as surface water, groundwater, domestic sewage, and industrial wastewater.
HK-8610 Automatic Recognition System for Two Insect Detection
Through long-term and in-depth cooperation with the Ecological Environment Research Center of the Chinese Academy of Sciences, and referring to the research progress at home and abroad and the actual situation of domestic water quality testing, with the goal of reducing equipment and testing costs, Beijing Huakeyi Technology Co., Ltd. has carried out systematic research and development around the "two pests" detection methods, instrument development, automatic identification system and other aspects, developed the "two pests" detection automatic identification system based on "membrane concentration/density gradient separation fluorescent antibody method" and artificial intelligence technology, which has solved many problems such as high detection cost, subjective and technical problems of manual identification, dependence on imported products and equipment and many other problems in the "two pests" detection process of drinking water in China.
Chemical Oxygen Demand (CODcr) online monitoring instrument
Chemical Oxygen Demand (COD) refers to the mass concentration of oxidants consumed under certain conditions when using strong oxidants to oxidize organic and inorganic reducing substances in water samples. COD reflects the degree of pollution of water by organic and inorganic reducing substances.
The instrument adopts automatic control for water sample collection, digestion and oxidation, reaction measurement, data processing and transmission, and quickly and continuously completes the entire process of COD analysis in wastewater.
The instrument is designed according to the oxidation principle of potassium dichromate method. In the experiment, a known amount of potassium dichromate solution is added, and silver sulfate is used as a catalyst in a strong sulfuric acid medium. After high-temperature digestion, the chemical oxygen demand (COD) value is determined by spectrophotometry.