Company | USIDEAL INSTRUMENTS CO,.LTD. |
Country | China |
Products | Process measuring and control technology Mechanical installations and control technology Electronic installations Treatment of volatile organic compounds(VOCs) Desulphurization and denitrification Analysis and laboratory techniques Environmental monitoring techniques and equipment Universities Research institutes Trade associations and institutions |
Hall | N2 |
Booth | A73 |
Website | www.usideal.cn |
Introduction | USIDEAL INSTRUMENTS CO,.LTD. established in Zibo City, Shandong Province is dedicated to the R & D and design of UV ozone concentration analyzer, ozone purification equipment and disinfection equipment. The company has always been oriented by ozone analysis technology and is a technology-based enterprise in the ozone industry. The company mainly engaged in the R & D, production, sales and technical services of instruments.The company actively relies on the advantages of high-level technical talents, and focuses on the research and development of new products with international market. |
Products
UVOZ-3300C wall mounted ozone concentration analyzer Based on Lambert Bill's law, the analyzer of UVOZ-3300C by measuring the change of the intensity of the light signal before and after the UV absorption to calculate the current ozone concentration. The equipment adopts the advanced dual UV light source system with the intelligent management system of the lamp tube and separated photocell technology enables the analyzer has the characteristics of no leakage, anti high pressure, anti large-flow sampling gas impact. The ozone analyzer has a touch screen operation interface, which shows the real-time ozone concentration. And the touch screen is also with the pressure &temperature compensation display. For the high concentration (g/Nm3) range, it has the function of flow input, which can display the output of the ozone generator in real time. The core component adopts long-life UV light system with the high light transmittance quartz to prevent zero drifting from affecting the detection accuracy. And no need to close ozone inputting at zeroing to ensure the equipment can run continuously 24 hours. Application areas: ozone generator manufacturers, municipal water industry, industrial sewage industry, fine chemical industry food and drinking water industry, space disinfection industry, swimming pool disinfection industry, etc. |
|
UVOZ1200 desk-top ozone concentration analyzer Based on Lambert Bill's law, the analyzer of UVOZ-1200 by measuring the change of the intensity of the light signal before and after the UV absorption to calculate the current ozone concentration. The equipment adopts the advanced dual UV light source system with the intelligent management system of the lamp tube and separated photocell technology enables the analyzer has the characteristics of no leakage, anti high pressure, anti large-flow sampling gas impact. The ozone analyzer has a touch screen operation interface, which shows the real-time ozone concentration. And the touch screen is also with the pressure & temperature compensation display. For the high concentration (g/Nm3) range, it has the function of flow input, which can display the output of the ozone generator in real time. The core component adopts long-life uv light system with the high light transmittance quartz to prevent zero drifting from affecting the detection accuracy. And no need to close ozone inputing at zeroing to ensure the equipment can run continuously 24 hours. Application areas: ozone generator manufacturers, municipal water industry, industrial sewage industry, fine chemical industry food and drinking water industry, space disinfection industry, swimming pool disinfection industry, etc. |
|
UV-2300C wall mounted ozone concentration analyzer UV-2300C ozone analyzer is equipped with touch screen operation interface, which can display the concentration of ozone gas in real time, with pressure and temperature compensation and display, and can set automatic zero calibration time and manual zero calibration mode. High concentration (g / Nm3) range with flow input function can display the output of ozone generator in real time. With two sets of relay signal output, users can freely choose high alarm point and low alarm point signal output connection. The core component adopts ultraviolet long-life light source system and high transmittance quartz plate to ensure the stability of zero point and prevent zero drift from affecting the accuracy of detection concentration. According to the independent light cell structure with pressure resistance and impact resistance designed by foreign light cell technology, the gas flow rate, pressure and flow rate remain unchanged during zero calibration operation, so as to prevent the impact of airflow impact on zero calibration. Zero calibration operation can be completed without closing ozone intake, and the equipment can operate continuously 24 hours a day. |
|
desk-top ozone concentration analyzer The ozone analyzer has touch screen operation interface, which shows the real-time ozone concentration. And the touch screen is also with pressure & temperature compensation display. For the high concentration (g/Nm3) range, it has the function of flow input, which can display the output of the ozone generator in real time. The core component adopts long-life UV light system with the high light transmittance quartz to prevent zero drifting from affecting the detection accuracy. It’s no need to close ozone inputting when zeroing to ensure the equipment can run continuously 24 hours |
|