Company | SHANGHAI SUNMOON ENVIRONMENTAL PROTECTION EQUIPMENT CO., LTD |
Country | China |
Products | Process measuring and control technology Environmental monitoring techniques and equipment |
Hall | E5 |
Booth | B72 |
Website | www.sunmoonepe.com |
Introduction |
Products
Water hardness analyzer TESTOMAT ECO Testomat ECO® determines water hardness fully automatically via titration. It is ideal for monitoring and controlling the water quality of water treatment and drinking-water plants. Performance profile: • Two-line LCD for displaying text and a self-explanatory, menu-driven operating interface • Programmable hardness unit in °dH, °f, ppm, CaCO3 and mmol/l • Accurate titration via piston-dosing pump • Reliable low maintenance operation • Minimum reagent and water consumption • Two adjustable limit values with programmable switch functions • Analysis initiation: – Automatic interval operation (0–99 min.) – Quality-dependent (impulse water meter) • The monitoring of the analysis run and error message, e.g. low water pressure • External analysis suppression “STOP” • Available quantity of indicator: 100 and 500 ml bottles • Analogue terminal 0/4–20 mA for a recorder • Menu Language with international language selection: DE, GB, FR, NL, PL, ES, IT |
|
Water hardness analyzer TESTOMAT EVO TH Testomat® EVO TH determines water hardness (residual total hardness) fully automatically via Titration. It is ideal for monitoring the water quality of water treatment, drinking-water plants, industrial Boilers and to monitoring the process water. Technical data: Power supply: 230 VAC ± 10%, 50 - 60 Hz or Wide-range power supply 100-240 VAC, 100 – 353 VDC Power Consumption: max. 30 VA Protection class: IP 65 Ambient Temperature: 10–40 °C Water Temperature: 10–40 °C Weight: approx. 9.0 kg Dimensions (W x H x D): 380 x 480 x 280 mm Working pressure: 1 to 8 bar / 1x105 to 8x105 Pa or 0,3* to 1 bar / 0,3x105 to 1x105 Pa (after removing the valve body) Menu Language: German, English, French, Dutch, Spanish, Turkish, (other languages on request) Measuring ranges: 0.05 – 25 °dH water hardness |
|
Water hardness analyzer TESTOMAT® 808 The Testomat® 808 is a compact analyzer for online measurement of water hardness on the principle of "limit value monitoring with color change". The Testomat® 808 represents a combination of the latest technology based upon decades of international Testomat experience. Applications of continuous residual hardness monitoring are for example: • Reverse osmosis plants • Boiler feed water supply • Soft water for commercial purposes • Pure water production plants Performance profile: • Total hardness measuring range: 0.02 - 5 °dH [0.02 / 0.05 / 0.1 / 0.2 / 0.3 / 0.5 / 1 / 2 / 3 / 5] °dH • Limit value indication (not exceeded or exceeded: green / red LED) • Modern reagent pump system and self-cleaning measuring chamber • Automatic measurement with low water consumption • Direct error and reagent quantity indication • Automatic or manual internal flushing of the measuring chamber • Control of an external rinsing valve • 3 potential-free relays: - External rinsing valve control - Limit value evaluation - External control and / or alarm processing • Safety check for 72 hours operation without supervision • Reagent quantities: 100 and 500 ml bottles • 4-20 mA interface for defined status and error messages • RS 232 interface for firmware updates Technical data: Power consumption: max. 16 VA Protection class: I Degree of Protection: IP 54 Ambient temperature: 15 – 40 °C (59 - 104 °F) Water temperature: 10 – 40 °C (50 - 104 °F) Operating pressure: 1 – 8 bar* Weight: 4.35 kg Dimensions (W x H x D): 364 x 314 x 138 mm |
|
residual total hardness (Carbonate hardness) analyzer TESTOMAT ECO® C Performance profile: • Simple, menu-driven operating and programming via a plain text display • Determinable measuring of total hardness (water hardness) • Freely selectable hardness unit in °dH, °f, ppm CaCO3 or mmol/ • High measuring accuracy provided by a precise piston-dosing pump • control of indicator dosage • Analysis initiation: - Automatic interval operation (interval pause can be set from 0-99 minutes) - Quantity dependent via impulse water meter/turbine - External analysis stop • Two independent limit values with hysteresis (1, 2 or 3 bad analyses) and settable switch functions (two neutral change-over contacts) • Fault message output (neutral change-over contact) • Current output 0/4 - 20 mA • Menu Language with international language selection: DE, GB, FR, NL, PL, ES, IT Technical data: Power consumption: max. 25 VA Protection class: I Degree of protection: IP 65 Ambient temperature: 10–45 °C (50-113 °F) Water temperature: 10–40 °C (50-104 °F) Operating pressure: 0.3–8 bar Weight: approx. 9.0 kg Dimensions (W x H x D): 380 x 480 x 280 mm Measuring ranges: 0.18 – 3.58 mmol/l Carbonate hardness 0.36 – 7.16 mmol/l Carbonate hardness |
|
Residual chlorine analyzer Testomat2000® THCL The Testomat 2000® THCl determines the content of total chlorine in the 0 to 2.5 mg/l (ppm) range using the colorimetric method and the existing water hardness via titration. Performance profile: • Two independently programmable limit value contacts for monitoring and controlling tasks; the analysis result is recorded via an optional plug-in card (current interface SK910) for a recorder (0/4–20 mA) or an SD-card data logger • Simple, menu-driven operating and programming via a plain text display • High measuring accuracy provided by a precise piston-dosing pump • Analysis initiation: – Dynamic start (Exhaustion dependent) – Automatic interval operation (Interval pause adjustable from 0–99 min.) – Volume controlled (water meter) – External control • Two independent limit values with hysteresis (1, 2 or 3 bad analyses) and adjustable switch functions • Monitoring of two measuring points (change-over via external solenoid valves) • Internal error documentation • Programmable service address • Reagent quantities: 100 and 500 ml bottles • Display of the date of the next maintenance and of the programmed maintenance interval. . |
|
Multi channel water monitoring system Disinfectants Free Chlorine, Chlorine Dioxide, Total Chlorine: up to 1000 µg/l, up to 5.00 / 10.00 / 20.00 mg/l Ozone: up to 1000µg/l, up to 5.00 / 10.00 mg/l Hydrogen Peroxide: up to 30.00 mg/l Temperature 0.. 50.0 °C (32.. 122 °F) pH 0.. 14.00 pH Redox potential (optional) -1500.. +1500 mV 5th measuring input (optional) Conductivity: up to 100,0 mS/cm 6th measuring input (optional / DIS 2) Free Chlorine, Total Chlorine: up to 1000 µg/l, up to 5.00 / 10.00 / 20.00 mg/l Digital inputs Flow control, external controller stop, 2x level control, activation 2nd or 3rd control parameter set StabiFlow® StabiFlow® is an assembly for precise measurement of disinfectants. The values are: Constant flow of approx. 30 l/h Stable, precise and reliable measurements Cost reduction due to increased life expectancy of the sensors ASR® ASR® is Kuntze's patented automatic sensor cleaning ASR® keeps the electrode surfaces clean and reduces maintenance efforts Available for Free Chlorine, Chlorine Dioxide, Ozone, and Hydrogen Peroxide Reduces the need for calibration Cost reduction due to less maintenance |
|