Company SHANGHAI SUNMOON ENVIRONMENTAL PROTECTION EQUIPMENT CO., LTD
Country China
Products Process measuring and control technology
Environmental monitoring techniques and equipment
Hall E5
Booth B72
Website www.sunmoonepe.com
Introduction

Products

Water hardness analyzer TESTOMAT ECO
Testomat ECO®
determines water hardness fully automatically via
titration. It is ideal for monitoring and controlling the water quality of water
treatment and drinking-water plants.
Performance profile:
• Two-line LCD for displaying text and a self-explanatory, menu-driven
operating interface
• Programmable hardness unit in °dH, °f, ppm, CaCO3 and mmol/l
• Accurate titration via piston-dosing pump
• Reliable low maintenance operation
• Minimum reagent and water consumption
• Two adjustable limit values with programmable switch functions
• Analysis initiation:
– Automatic interval operation (0–99 min.)
– Quality-dependent (impulse water meter)
• The monitoring of the analysis run and error message, e.g. low water
pressure
• External analysis suppression “STOP”
• Available quantity of indicator: 100 and 500 ml bottles
• Analogue terminal 0/4–20 mA for a recorder
• Menu Language with international language selection: DE, GB, FR,
NL, PL, ES, IT
Water hardness analyzer TESTOMAT EVO TH
Testomat®
EVO TH determines water hardness (residual total hardness)
fully automatically via Titration. It is ideal for monitoring the water quality
of water treatment, drinking-water plants, industrial Boilers and to
monitoring the process water.
Technical data:
Power supply: 230 VAC ± 10%, 50 - 60 Hz or
Wide-range power supply 100-240 VAC,
100 – 353 VDC
Power Consumption: max. 30 VA
Protection class: IP 65
Ambient Temperature: 10–40 °C
Water Temperature: 10–40 °C
Weight: approx. 9.0 kg
Dimensions (W x H x D): 380 x 480 x 280 mm
Working pressure: 1 to 8 bar / 1x105
to 8x105
Pa or
0,3* to 1 bar / 0,3x105
to 1x105
Pa
(after removing the valve body)
Menu Language: German, English, French, Dutch, Spanish,
Turkish,
(other languages on request)
Measuring ranges: 0.05 – 25 °dH water hardness
Water hardness analyzer TESTOMAT® 808
The Testomat®
808 is a compact analyzer for online measurement of
water hardness on the principle of "limit value monitoring with color
change". The Testomat®
808 represents a combination of the latest
technology based upon decades of international Testomat experience.
Applications of continuous residual hardness monitoring are for example:
• Reverse osmosis plants
• Boiler feed water supply
• Soft water for commercial purposes
• Pure water production plants
Performance profile:
• Total hardness measuring range: 0.02 - 5 °dH
[0.02 / 0.05 / 0.1 / 0.2 / 0.3 / 0.5 / 1 / 2 / 3 / 5] °dH
• Limit value indication (not exceeded or exceeded: green / red LED)
• Modern reagent pump system and self-cleaning measuring
chamber
• Automatic measurement with low water consumption
• Direct error and reagent quantity indication
• Automatic or manual internal flushing of the measuring chamber
• Control of an external rinsing valve
• 3 potential-free relays:
- External rinsing valve control
- Limit value evaluation
- External control and / or alarm processing
• Safety check for 72 hours operation without supervision
• Reagent quantities: 100 and 500 ml bottles
• 4-20 mA interface for defined status and error messages
• RS 232 interface for firmware updates
Technical data:
Power consumption: max. 16 VA
Protection class: I
Degree of Protection: IP 54
Ambient temperature: 15 – 40 °C (59 - 104 °F)
Water temperature: 10 – 40 °C (50 - 104 °F)
Operating pressure: 1 – 8 bar*
Weight: 4.35 kg
Dimensions (W x H x D): 364 x 314 x 138 mm
residual total hardness (Carbonate hardness) analyzer TESTOMAT ECO® C
Performance profile:
• Simple, menu-driven operating and programming via a plain text display
• Determinable measuring of total hardness (water hardness)
• Freely selectable hardness unit in °dH, °f, ppm CaCO3 or mmol/
• High measuring accuracy provided by a precise piston-dosing pump
• control of indicator dosage
• Analysis initiation:
- Automatic interval operation
(interval pause can be set from 0-99 minutes)
- Quantity dependent via impulse water meter/turbine
- External analysis stop
• Two independent limit values with hysteresis (1, 2 or 3 bad analyses)
and settable switch functions
(two neutral change-over contacts)
• Fault message output (neutral change-over contact)
• Current output 0/4 - 20 mA
• Menu Language with international language selection: DE, GB, FR,
NL, PL, ES, IT
Technical data:
Power consumption: max. 25 VA
Protection class: I
Degree of protection: IP 65
Ambient temperature: 10–45 °C (50-113 °F)
Water temperature: 10–40 °C (50-104 °F)
Operating pressure: 0.3–8 bar
Weight: approx. 9.0 kg
Dimensions (W x H x D): 380 x 480 x 280 mm
Measuring ranges: 0.18 – 3.58 mmol/l Carbonate hardness
0.36 – 7.16 mmol/l Carbonate hardness
Residual chlorine analyzer Testomat2000® THCL
The Testomat 2000®
THCl determines the content of total chlorine in the
0 to 2.5 mg/l (ppm) range using the colorimetric method and the existing
water hardness via titration.
Performance profile:
• Two independently programmable limit value contacts for monitoring
and controlling tasks; the analysis result is recorded via an optional
plug-in card (current interface SK910) for a recorder (0/4–20 mA) or an
SD-card data logger
• Simple, menu-driven operating and programming via a plain text
display
• High measuring accuracy provided by a precise piston-dosing pump
• Analysis initiation:
– Dynamic start (Exhaustion dependent)
– Automatic interval operation (Interval pause adjustable from 0–99 min.)
– Volume controlled (water meter)
– External control
• Two independent limit values with hysteresis (1, 2 or 3 bad analyses)
and adjustable switch functions
• Monitoring of two measuring points (change-over via external solenoid
valves)
• Internal error documentation
• Programmable service address
• Reagent quantities: 100 and 500 ml bottles
• Display of the date of the next maintenance and of the programmed
maintenance interval.
.
Multi channel water monitoring system
Disinfectants

Free Chlorine, Chlorine Dioxide, Total Chlorine: up to 1000 µg/l, up to 5.00 / 10.00 / 20.00 mg/l

Ozone: up to 1000µg/l, up to 5.00 / 10.00 mg/l

Hydrogen Peroxide: up to 30.00 mg/l

Temperature

0.. 50.0 °C (32.. 122 °F)

pH

0.. 14.00 pH

Redox potential (optional)

-1500.. +1500 mV

5th measuring input (optional)

Conductivity: up to 100,0 mS/cm

6th measuring input (optional / DIS 2)

Free Chlorine, Total Chlorine: up to 1000 µg/l, up to 5.00 / 10.00 / 20.00 mg/l
Digital inputs

Flow control, external controller stop, 2x level control, activation 2nd or 3rd control parameter set

StabiFlow®
StabiFlow® is an assembly for precise measurement of disinfectants. The values are:

Constant flow of approx. 30 l/h

Stable, precise and reliable measurements

Cost reduction due to increased life expectancy of the sensors

ASR®
ASR® is Kuntze's patented automatic sensor cleaning

ASR® keeps the electrode surfaces clean and reduces maintenance efforts
Available for Free Chlorine, Chlorine Dioxide, Ozone, and Hydrogen Peroxide
Reduces the need for calibration
Cost reduction due to less maintenance